How do I…

Place an Other or a Relay and name it

Place an Other for anything the Palette has no picture for, or a Relay for a contact closure, and type its Name so the plan, the equipment list and the printed sheet say what it is, such as OTH-1 · Gate motor.

Where to find it: Palette › Equipment › Infrastructure › Other, or Control & Voice › Relay; its name is in Properties › Name

Other is one icon for anything the Palette has no picture for: a gate motor, a pool pump, a fireplace damper. It is a taupe diamond with three dots, and it counts on its own as OTH-1, OTH-2. The name is what makes it readable, so give each one.

Relay is a teal chip with the open contact of a relay schematic, for a non-fire contact closure: a gate, a garage door, a fireplace, a lift, a pool cover, a screen trigger. It counts as RLY-1, RLY-2 whatever its channels; put the brand and channel count in the model. The fire alarm's relay module stays in Fire & Life Safety.

  1. Open Palette › Equipment and click Other in Infrastructure, or Relay in Control & Voice.
  2. Click on the sheet where it goes. Keep clicking to place more, or choose Done.
  3. Select the device. In Properties, type Name at the top, such as Gate motor, and press Enter.

Its label then reads OTH-1 · Gate motor on the drawing and on every printed sheet. The name is one line of up to 40 characters; spaces are trimmed, and typing nothing takes the name away. The number itself stays OTH-1 in search, in the lists and in the schedules.

Select several and Name reads Mixed where they differ; typing one gives them all the same name, in one undo step (see change several devices at once).

The equipment list has a row for each distinct name, such as Other · Gate motor, and the unnamed ones together. The legend has one row for the picture, Other, whatever the names.

A relay starts with an 18/2 control cable; an Other starts with none. Add or change cables as for any icon: see cabling defaults.

The other everyday icons

Four more icons come with them, each with its own code and count:

  • IR · Receiver and IR · Emitter (IR), in Control & Voice: one count, IR-1, IR-2, drawn as an eye and as a body with straight rays.
  • Occupancy sensor (OCC), at the end of Lighting control's wireless part: a violet disc with a person in it, apart from the alarm's motion detectors.
  • Antenna / dish (ANT), at the end of Network: a bowl with its feed, in blue.
  • Smart lock (LCK), in Access Control beside the strike and the mag lock: a purple plate with a keyhole. Like them, it joins a door.

They start with 18/2 for the IR icons and the occupancy sensor, the region's coax for the dish, and no cable for the smart lock, which runs on a battery. See place a device for the Palette, and device.